Second-stage bioassay pre-training · 5×5 cross validation · two data sets

What a PCBA stage buys a 3D encoder

Atom-JEPA-Bio1 continues the released Atom-JEPA encoder2 with a second pre-training stage that adds a supervised loss over 1,089 PCBA bioassays3 to its self-supervised objectives, and fine-tunes it on ADMET exactly as before. Its authors scored it on this site's protocol and report it best or tied on 34 of 45 endpoint × metric combinations, against 18 for Monroe + TabPFN 34. Run here with their code and weights, on the same folds, the count comes out at 35 against 17. Only the checkpoint differs from the Atom-JEPA study, so the bioassay stage can be measured directly: fine-tuned, it is ahead of stage 1 on 32 of the 45 paired calls and behind on one. On Biogen it turns a deficit against Monroe into a lead: stage 1 was behind on 13 of 18 combinations, Bio is ahead on 12.

7methods compared
15endpoints
5×5cross validation
55fine-tuned fold models
27GPU hours

One checkpoint swapped

The fine-tuned arm is the authors' train_multitask from github.com/khelverskovp/atom-jepa at commit 64d539b, whose fine-tuning configuration is identical to the commit the stage-1 study ran. It reads the bio encoder from the Hugging Face Hub in place of molecules, and nothing else changes: one multitask model per fold, the encoder frozen for ten of fifty epochs, ten RDKit conformers per molecule — the very conformer files the stage-1 study used — and the test prediction averaged over all ten. The best epoch is picked on the held-out fifth of the training set and every arm is scored on the same untouched test set.

Two frozen arms read the stage-1 and the Bio encoder, eight layers mean-pooled, through the TabPFN 35 call the Monroe arm makes; both are fitted here, on the same machine. LightGBM on Morgan counts6, ChemProp fine-tuned from CheMeleon7 and Monroe + TabPFN 3 are imported from the nine-method foundation-model comparison, and stage-1 Atom-JEPA fine-tuned from the Atom-JEPA study, none of them re-run.

The scoreboard

Tukey HSD per endpoint and metric over all seven arms, counted the way every page on this site counts: a method is on top if Tukey's correction cannot separate it from the best mean, and only best alone if nothing else is on top with it. The tables show MAE, in the units of each endpoint.

ExpansionRx8

LightGBM + Morgan0 best alone · 0 tied for best · 27 worse
ChemProp + CheMeleon, fine-tuned0 best alone · 3 tied for best · 24 worse
Monroe + TabPFN 37 best alone · 2 tied for best · 18 worse
Atom-JEPA frozen + TabPFN 30 best alone · 0 tied for best · 27 worse
Atom-JEPA fine-tuned0 best alone · 15 tied for best · 12 worse
Atom-JEPA-Bio frozen + TabPFN 30 best alone · 0 tied for best · 27 worse
Atom-JEPA-Bio fine-tuned4 best alone · 16 tied for best · 7 worse
EndpointLightGBMCheMeleon FTMonroe/PFN3Atom-JEPA/PFN3Atom-JEPA FTBio/PFN3Bio FT
LogD0.545±0.0120.427±0.0180.402±0.0150.483±0.0110.382±0.0140.434±0.0100.346±0.013best
LogS0.454±0.0150.358±0.0170.380±0.0090.434±0.0150.323±0.010tied0.397±0.0120.322±0.011tied
LOG_HLM0.332±0.0090.314±0.0140.293±0.0090.298±0.0090.277±0.014tied0.297±0.0080.274±0.012tied
LOG_MLM0.410±0.0140.399±0.0300.358±0.011best0.385±0.0140.390±0.0170.379±0.0160.388±0.017
LOG_Caco_AB0.340±0.0220.305±0.0330.248±0.011best0.318±0.0170.314±0.0370.306±0.0200.281±0.032
LOG_Caco_Efflux0.432±0.0190.375±0.0340.346±0.012best0.404±0.0160.375±0.0340.415±0.0170.367±0.035
LOG_MPPB0.288±0.0200.212±0.0210.259±0.0130.286±0.0170.185±0.018tied0.256±0.0110.190±0.017tied
LOG_MBPB0.223±0.0180.157±0.0180.192±0.0160.190±0.0100.124±0.005tied0.177±0.0100.125±0.008tied
LOG_MGMB0.302±0.0340.175±0.015tied0.204±0.0330.199±0.0140.163±0.010tied0.206±0.0230.168±0.013tied
Tukey HSD on MAE, ExpansionRx. Each bar is a method's mean over 25 folds with an interval widened to cover every pairwise comparison at once. Blue is the best mean, grey cannot be separated from it, red is worse.
Tukey HSD on MAE, ExpansionRx. Each bar is a method's mean over 25 folds with an interval widened to cover every pairwise comparison at once. Blue is the best mean, grey cannot be separated from it, red is worse.

Biogen ADME9

LightGBM + Morgan0 best alone · 0 tied for best · 18 worse
ChemProp + CheMeleon, fine-tuned0 best alone · 0 tied for best · 18 worse
Monroe + TabPFN 31 best alone · 7 tied for best · 10 worse
Atom-JEPA frozen + TabPFN 30 best alone · 0 tied for best · 18 worse
Atom-JEPA fine-tuned0 best alone · 0 tied for best · 18 worse
Atom-JEPA-Bio frozen + TabPFN 32 best alone · 7 tied for best · 9 worse
Atom-JEPA-Bio fine-tuned6 best alone · 8 tied for best · 4 worse
EndpointLightGBMCheMeleon FTMonroe/PFN3Atom-JEPA/PFN3Atom-JEPA FTBio/PFN3Bio FT
LOG_SOL0.413±0.0090.370±0.0070.322±0.0040.359±0.0050.340±0.0060.310±0.002tied0.310±0.007tied
LOG_HLM0.395±0.0050.337±0.0070.299±0.0030.338±0.0030.295±0.0080.293±0.0020.275±0.012best
LOG_RLM0.470±0.0050.404±0.0060.375±0.0030.405±0.0040.385±0.0050.367±0.0020.355±0.006best
LOG_MDR1_ER0.385±0.0050.340±0.0040.294±0.002tied0.337±0.0020.317±0.0050.296±0.004tied0.306±0.013
LOG_HPPB0.576±0.0330.558±0.0250.438±0.0170.537±0.0190.500±0.0190.430±0.021tied0.417±0.017tied
LOG_RPPB0.554±0.0210.553±0.0230.445±0.0260.551±0.0210.513±0.0230.411±0.017best0.434±0.023
Tukey HSD on MAE, Biogen ADME.
Tukey HSD on MAE, Biogen ADME.

Fine-tuned Bio is on top of 20 of 27 ExpansionRx combinations and 14 of 18 Biogen ones; Monroe + TabPFN 3 of 9 and 8; stage-1 Atom-JEPA fine-tuned of 15 and 0.

The authors' count, recomputed

The authors' tables compare six arms — the stage-1 frozen arm is not among them — and import the comparators' per-fold results from this site, as this study does. Restricting the Tukey test to the same six arms, so that the intervals are as wide as theirs, gives the counts below beside the ones on their page.

Best or tied for bestExpansionRx, of 27Biogen, of 18Both, of 45
authorshereauthorshereauthorshere
Atom-JEPA-Bio fine-tuned202114143435
Atom-JEPA-Bio frozen + TabPFN 3088
Monroe + TabPFN 399981817
Atom-JEPA fine-tuned14014
LightGBM + Morgan000
ChemProp + CheMeleon, fine-tuned303

The count is within one of theirs: 35 of 45 for fine-tuned Bio against their 34, 17 for Monroe against their 18. The fine-tuned folds here are a separate training of the same recipe, not the authors' fold models, so an exact match was not to be expected; the comparators' folds are the same in both.

The bioassay stage, measured

Paired by fold, fine-tuned Bio against fine-tuned stage-1 Atom-JEPA is ahead on three of the 9 endpoints on all three metrics and split on the other six (14 ahead and 1 behind of 27 endpoint × metric combinations) on ExpansionRx and ahead on all six endpoints on all three metrics (18 of 18 endpoint × metric combinations) on Biogen. The loss is LOG_MGMB MAE on ExpansionRx, by 0.0045 with 9 of 25 folds better, one of the pair's 45 uncorrected tests. It raises mean R² on 14 of 15 endpoints, by a median +0.024 on ExpansionRx and +0.067 on Biogen. Frozen and read by TabPFN 3 the stage does more: the Bio embedding is ahead of the stage-1 one on 37 of 45 combinations and behind on two, a median +0.057 R² on ExpansionRx and +0.109 on Biogen, and better on 13 of 15 endpoints.

PairExpansionRx, 27Biogen, 18Gain, mean of 15
winsno calllosseswinsno calllossesΔ R²MAE drop
Atom-JEPA-Bio fine-tuned against Atom-JEPA fine-tuned141211800+0.053+0.0218
Atom-JEPA-Bio frozen + TabPFN 3 against Atom-JEPA frozen + TabPFN 319621800+0.079+0.0368
Atom-JEPA-Bio fine-tuned against Monroe + TabPFN 318271233+0.048+0.0198
Atom-JEPA fine-tuned against Monroe + TabPFN 318093213−0.005−0.0020
Atom-JEPA-Bio frozen + TabPFN 3 against Monroe + TabPFN 346171134−0.047−0.0078
Atom-JEPA-Bio fine-tuned against Atom-JEPA-Bio frozen + TabPFN 325111044+0.095+0.0276
Atom-JEPA-Bio fine-tuned against ChemProp + CheMeleon, fine-tuned26101800+0.130+0.0484
Atom-JEPA-Bio fine-tuned against LightGBM + Morgan27001800+0.287+0.1039
Fine-tuned Bio against each arm on ExpansionRx: mean paired MAE difference over 25 folds with a 95% interval, drawn in the comparator's colour and signed so that right of zero is Bio better.
Fine-tuned Bio against each arm on ExpansionRx: mean paired MAE difference over 25 folds with a 95% interval, drawn in the comparator's colour and signed so that right of zero is Bio better.
The same on Biogen ADME.
The same on Biogen ADME.

Not the machine

Stage-1 Atom-JEPA was fine-tuned for the earlier study on an RTX 5070 Ti and a DGX Spark, and every Bio fold on Biogen on an RTX PRO 5000. To see how far a change of machine moves the same recipe on its own, the stage-1 arm was re-trained here on the 5 folds of Biogen's first repeat. The re-run lands within 0.007 R² of the imported folds on every endpoint; Bio is at least 0.039 above them on every endpoint.

EndpointAtom-JEPA FT, importedAtom-JEPA FT, re-run hereRe-run − importedBio FTBio − imported
LOG_SOL0.4370.432−0.0050.508+0.072
LOG_HLM0.5680.561−0.0070.617+0.049
LOG_RLM0.5630.558−0.0050.617+0.054
LOG_MDR1_ER0.5810.585+0.0040.620+0.039
LOG_HPPB0.4000.405+0.0050.533+0.133
LOG_RPPB0.3270.321−0.0060.463+0.136

Against Monroe

Fine-tuned Bio is ahead on six and behind on one of the 9 endpoints on all three metrics and split on the other two (18 ahead and 7 behind of 27 endpoint × metric combinations) on ExpansionRx, and ahead on three and behind on one of the 6 endpoints on all three metrics and split on the other two (12 ahead and 3 behind of 18 endpoint × metric combinations) on Biogen. Stage-1 Atom-JEPA, against the same Monroe folds, had been 18 ahead and 9 behind on ExpansionRx and 3 ahead and 13 behind on Biogen. Frozen, the Bio embedding is ahead of Monroe's on Biogen (11 ahead, 4 behind) and behind it on ExpansionRx (4 ahead, 17 behind); fine-tuning is still what wins, ahead of the frozen Bio arm on 35 of 45 paired calls and behind on five.

EndpointData setBioassay stage, frozen: Bio − Atom-JEPA, both + TabPFN 3Bioassay stage, fine-tuned: Bio − Atom-JEPAMonroe's embedding → Bio's, same TabPFN 3Then fine-tune Bio insteadBio fine-tuned − Monroe
LOG_HLMBiogen ADME+0.103+0.050+0.023+0.044+0.067
LOG_HPPBBiogen ADME+0.210+0.126−0.019+0.058+0.038
LOG_MDR1_ERBiogen ADME+0.097+0.040−0.011−0.006−0.017
LOG_RLMBiogen ADME+0.079+0.056+0.030+0.022+0.051
LOG_RPPBBiogen ADME+0.272+0.136−0.005+0.045+0.039
LOG_SOLBiogen ADME+0.116+0.077+0.041−0.032+0.008
LOG_Caco_ABExpansionRx+0.057+0.176−0.280+0.088−0.192
LOG_Caco_EffluxExpansionRx−0.071+0.026−0.362+0.226−0.137
LOG_HLMExpansionRx+0.002+0.024−0.014+0.112+0.097
LOG_MBPBExpansionRx+0.057+0.008+0.050+0.164+0.214
LOG_MGMBExpansionRx−0.016+0.004−0.009+0.096+0.087
LOG_MLMExpansionRx+0.018+0.011−0.101+0.004−0.096
LOG_MPPBExpansionRx+0.134−0.008+0.005+0.326+0.331
LogDExpansionRx+0.063+0.046−0.027+0.109+0.082
LogSExpansionRx+0.058+0.024−0.027+0.171+0.145
medianBiogen ADME+0.109+0.067+0.009+0.033+0.039
medianExpansionRx+0.057+0.024−0.027+0.112+0.087

Where it still loses is where stage 1 lost. On ExpansionRx it is behind Monroe on every metric of LOG_MLM, on Biogen on LOG_MDR1_ER, and on some metrics of LOG_Caco_AB and LOG_Caco_Efflux. Caco-2 A→B remains Monroe's: an R² of 0.471 ± 0.041 over the 25 folds against 0.279 ± 0.185 for fine-tuned Bio and 0.103 ± 0.219 for stage 1. Across the fifteen endpoints, the rank correlation between molecules per training fold and Bio's margin over Monroe is −0.09.

Monroe + TabPFN 3 against fine-tuned Bio, MAE paired by fold, Biogen ADME. Each line is one fold.
Monroe + TabPFN 3 against fine-tuned Bio, MAE paired by fold, Biogen ADME. Each line is one fold.

Was it pre-trained on the test set?

Stage 2 trains on PCBA as Monroe's pipeline prepares it, which moves the test splits of the public benchmarks out of training — but those are the Polaris splits of the Biogen data, not this site's. Matching every test molecule to the PCBA table by standard InChI, Monroe's own deduplication key, finds 162 of Biogen's 1,058 test molecules (15%) and none of ExpansionRx's 2,282. That is an upper bound on what reached training. The assays are rarely ADMET: one solubility assay, AID 1996, labels 12 of the matched Biogen molecules. Monroe's pre-training draws on the same table, so any exposure is shared by the arm Bio is compared with.

Scoring the Biogen test set in two halves:

EndpointTest moleculesnBio FT MAEAtom-JEPA FT MAEMonroe/PFN3 MAEBio − Atom-JEPABio − Monroe
LOG_SOLnot in PCBA5660.2800.3130.297−0.034−0.017
LOG_SOLin PCBA1060.4740.4820.459−0.008+0.014
LOG_HLMnot in PCBA7970.2730.2930.289−0.020−0.016
LOG_HLMin PCBA1320.2910.3100.360−0.018−0.069
LOG_RLMnot in PCBA7900.3530.3840.371−0.031−0.018
LOG_RLMin PCBA1320.3700.3880.397−0.018−0.028
LOG_MDR1_ERnot in PCBA6950.2950.3040.287−0.010+0.008
LOG_MDR1_ERin PCBA1090.3800.4010.343−0.021+0.037
LOG_HPPBnot in PCBA510.3730.4780.390−0.105−0.017
LOG_HPPBin PCBA150.5670.5780.601−0.011−0.033
LOG_RPPBnot in PCBA440.3990.4860.377−0.087+0.022
LOG_RPPBin PCBA150.5350.5930.644−0.058−0.109

On the molecules PCBA does not have, fine-tuned Bio is still below stage 1 in MAE on all six endpoints and below Monroe on LOG_HLM, LOG_HPPB, LOG_RLM and LOG_SOL. The molecules PCBA has are harder, not easier: Monroe's MAE is higher on them on all six endpoints. The gain does not come from having seen the test set.

What it costs

The recipe is unchanged, and so is the cost: a median 62 minutes per ExpansionRx fold on the RTX 5070 Ti against 59 for stage 1 on the same card. The Bio folds ran on two machines, 37 on an RTX PRO 5000 Blackwell and 13 on an RTX 5070 Ti, each fold from its own seed, with the claimed folds of each machine skipped by the other.

Data setArmMachineFoldsMedian min / foldMedian best epoch of 50Peak GPU memory, GBTotal, GPU hours
Biogen ADMEAtom-JEPA fine-tuned (re-run)mercury, RTX PRO 5000 Blackwell5143514.21.1
Biogen ADMEAtom-JEPA-Bio fine-tunedmercury, RTX PRO 5000 Blackwell25121914.25.1
ExpansionRxAtom-JEPA-Bio fine-tunedapollo, GeForce RTX 5070 Ti13622811.113.5
ExpansionRxAtom-JEPA-Bio fine-tunedmercury, RTX PRO 5000 Blackwell12352911.47.2

What this does and does not say

Scope

One recipe. The fine-tuning hyperparameters are the authors' and are used unchanged on both data sets, as in the stage-1 study. Nothing is tuned for Monroe either.

Conformers are pinned. RDKit's conformer generator does not give the same conformers across releases even with a fixed seed: a newer RDKit changed them for about a third of the Biogen molecules, and that alone moved the frozen stage-1 arm by up to 0.10 R² on the plasma-binding endpoints. Every Atom-JEPA arm here reads the stage-1 study's conformer files, checked by hash.

An upper bound on exposure. The PCBA match is by structure, before the authors' hold-out of the benchmark test splits, which could not be reproduced here. The real overlap with what stage 2 trained on is at most what is reported.

Reported the way “Even More Thoughts on ML Method Comparisons” and the protocol paper it points at10 argue comparisons should be: distributions over folds, simultaneous confidence intervals, paired tests on the folds, and no bolded maxima. A win or a loss in the paired tables is a t-test at p < 0.05 on one endpoint and one metric, uncorrected.

Code, per-fold metrics and every figure: studies/atom-jepa-bio.

References

  1. Petersen, K. H.; Tirsgaard, R. H.; Larsen, L. F.; Cornet, F. R. J.; Jordahn, M.; Schmidt, M. N. Atom-JEPA-Bio: Improving Atom-JEPA's ADMET Predictions with Second-Stage Pretraining. Blog post, November 2026. The method and the claim this page puts to the test, run with the authors' code (github.com/khelverskovp/atom-jepa) and their released bio encoder (huggingface.co/atom-jepa/atom-jepa). atom-jepa-website
  2. Petersen, K. H.; Tirsgaard, R. H.; Cornet, F. R. J.; Jordahn, M.; Schmidt, M. N. Atom-JEPA: Joint-Embedding Predictive Architecture for 3D Atomistic Systems. Preprint, 2026. The stage-1 encoder Atom-JEPA-Bio continues. arXiv:2610.08400
  3. Beaini, D.; Huang, S.; Cunha, J. A.; et al. Towards Foundational Models for Molecular Learning on Large-Scale Multi-Task Datasets. ICLR 2024. The 1,328-assay PCBA table both pre-trainings draw on (Zenodo 8024997). arXiv:2310.04292
  4. Banaszewski, B.; Fitzgibbon, A. W. Monroe: A Molecular Foundation Model for In-Context Probabilistic Inference. Preprint, 2026. The frozen encoder of the strongest arm on this site, pre-trained on the same PCBA preparation. arXiv:2608.18982
  5. Grinsztajn, L.; Flöge, K.; Key, O.; et al. TabPFN-3: Technical Report. Preprint, 2026. The head of the three frozen arms. arXiv:2605.13986
  6. Rogers, D.; Hahn, M. Extended-Connectivity Fingerprints. J. Chem. Inf. Model. 2010, 50 (5), 742–754. 10.1021/ci100050t
  7. Burns, J. W.; Zalte, A. S.; Abreu, C. R. A.; et al. Deep Learning Foundation Models for Low-Data Regimes from Classical Molecular Descriptors. J. Chem. Inf. Model. 2026, articles ASAP. 10.1021/acs.jcim.6c01546
  8. OpenADMET; Expansion Therapeutics. OpenADMET–ExpansionRx Blind Challenge Data. Hugging Face, 2026, CC BY 4.0. 10.57967/hf/9687
  9. Fang, C.; Wang, Y.; Grater, R.; et al. Prospective Validation of Machine Learning Algorithms for Absorption, Distribution, Metabolism, and Excretion Prediction: An Industrial Perspective. J. Chem. Inf. Model. 2023, 63 (11), 3263–3274. 10.1021/acs.jcim.3c00160
  10. Ash, J. R.; Wognum, C.; Rodríguez-Pérez, R.; et al. Practically Significant Method Comparison Protocols for Machine Learning in Small Molecule Drug Discovery. J. Chem. Inf. Model. 2025, 65 (18), 9398–9411. 10.1021/acs.jcim.5c01609